EU-Hybrid Inverter 3600W Single Phase
SW2436V120-500P 3600W EU single-phase hybrid solar inverter, supporting PV & diesel dual input, max 500V PV voltage. With zero export, UPS 10ms switching, 200% surge power, compatible lithium/lead-acid batteries for off-grid & backup home energy.
| SW2436V120-500P | ||
| Parallel mode | ||
| Permitted parallel number | NO | |
| ACmode | ||
| Rated input voltage | 230Vac±5% | |
| Input voltage range | (170Vac~280Vac)±2%; (90Vac-280Vac)±2% | |
| Frequency | 50Hz/60Hz(Auto detection) | |
| Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz);57±0.3Hz~65±0.3Hz(60Hz); | |
| Overload/short circuit protection | Circuit breaker | |
| Efficiency | >95% | |
| Conversion time(bypass and inverter) | 10ms(typical) | |
| AC reverse protection | Yes | |
| Maximum bypass overload current | 30A | |
| Inverter mode | ||
| Output voltage waveform | Pure sine wave | |
| Rated output power(VA) | 3600 | |
| Rated output power(W) | 3600 | |
| Power factor | 1 | |
| Rated output voltage (Vac) | 230Vac | |
| Output voltage error | +5% | |
| Output frequency range(Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | |
| Maximum Efficiency | >91% | |
| Overload protection | (102% report error and turn off theoutput after 5 minutes; (125% report error and turn off theoutput after 10 seconds; (Load>150%±10%): report errorand turn off the output after 5seconds; |
|
| Peak power | 7200VA | |
| Loaded motor capability | 2HP | |
| Output short circuit protection | Circuit breaker | |
| Bypass circuit breaker specification | 30A | |
| Rated battery input voltage | 30V(Minimum starting voltage 22V) | |
| Battery voltage range | 20.0Vdc~33Vdc+0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage alarm/ overvoltage recovery.settable on LCD screen) |
|
| Power saving mode self-consump tion | Load≤25W | |
| AC charging | ||
| Battery type | Lead acid or lithium battery | |
| Maximum charge current(can be set) | 80A | |
| Charge current error | +5Adc | |
| Charge voltage range | 20-33Vdc | |
| Short circuit protection | Circuit breaker and blown fuse | |
| Circuit breaker specifications | 30A | |
| PV charging | ||
| Maximum PV open circuit voltage | 500Vdc | |
| Start-up Voltage | 120V | |
| PV operating voltage range | 90-500Vdc | |
| MPPT voltage range | 90-450Vdc | |
| Battery voltage range | 20-33Vdc | |
| Maximum PVinput power | 6000W | |
| Maximum PVinput current | 27A | |
| PV charge current(can be set) | 0-120A | |
| Charging short circuit protection | Blown fuse | |
| Wiring protection | Reverse polarity protection | |
| Hybrid charging Max charger current specifications(AC charger+PV charger) | ||
| Max charger current(can be set) | 0-120A | |
| Certified specifications | ||
| Certification | CE(IEC62109-1,2) | |
| EMC certification leve | EN61000,C2 | |
| Operating temperature range | -10°Cto 55°C | |
| Storage temperature range | -25°C~60°C | |
| Humidity range | 5%to 95%(Conformal coating protection) | |
| Noise | ≤60dB | |
| Heat dissipation | Forced air cooling,variable speed of fan | |
| Communicati on interface | USB/RS485(/WiFi/GPRS)/Dry node control | |
| Size (L*W*D) | 428mm*280mm*110mm | |
| Weight(kg) | 8.2 | |