6200W EU parallel hybrid inverter
Model SW4862V100-500P 6200W EU parallel hybrid inverter, single phase, expandable up to 6 units. 200% surge power, 10ms UPS switch, 500V PV input, zero export function, works with lithium/lead-acid batteries for residential solar storage.
| SW4862V100-500P | ||
| Parallel mode | ||
| Permitted parallel number | 1-6 | |
| ACmode | ||
| Rated input voltage | 230Vac | |
| Input voltage range | (170Vac~280Vac)±2%@UPS (90Vac-280Vac)±2%@APL | |
| Frequency | 50Hz/60Hz(Auto detection) | |
| Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz);57±0.3Hz~65±0.3Hz(60Hz) | |
| Overload/short circuit protection | Circuit breaker | |
| Efficiency | >95% | |
| Conversion time(bypass and inverter) | 10ms(typical) | |
| AC reverse protection | Yes | |
| Maximum bypass overload current | 40A | |
| Inverter mode | ||
| Output voltage waveform | Pure sine wave | |
| Rated output power(VA) | 6200VA | |
| Rated output power(W) | 6200W | |
| Power factor | 1 | |
| Rated output voltage (Vac) | 230Vac | |
| Output voltage error | +5% | |
| Output frequency range(Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | |
| Maximum Efficiency | >92% | |
| Overload protection | (102% report errorand turn off the output after 5 minutes; (125% report error and turn off the output after 10 seconds; Load>150%+10%: report error and turn off the output after 5 seconds; |
|
| Peak power | 12000VA | |
| Loaded motor capability | 4HP | |
| Output short circuit protection | Circuit breaker | |
| Bypass circuit breaker specification | 40A | |
| Rated battery input voltage | 48V(Minimum starting voltage 44V) | |
| Battery voltage range | 40.0Vdc~60Vdc+0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage alarm/ overvoltage recovery..settable on LCD screen) |
|
| Power saving mode self-consump tion | Load≤25W | |
| AC charging | ||
| Battery type | Lead acid or lithium battery | |
| Maximum charge current(can be set) | 80A | |
| Charge current error | +5Adc | |
| Charge voltage range | 40-60Vdc | |
| Short circuit protection | Circuit breaker and blown fuse | |
| Circuit breaker specifications | 40A | |
| PV charging | ||
| Maximum PV open circuit voltage | 500Vdc | |
| PV operating voltage range | 120-500Vdc | |
| MPPT voltage range | 90-450Vdc | |
| Battery voltage range | 40-60Vdc | |
| Maximum PVinput power | 6000W | |
| Maximum PVinput current | 22A | |
| PV charge current(can be set) | 0-100A | |
| Charging short circuit protection | Blown fuse | |
| Wiring protection | Reverse polarity protection | |
| Hybrid charging Max charger current specifications(AC charger+PV charger) | ||
| Max charger current(can be set) | 0-100A | |
| Certified specifications | ||
| Certification | CE(IEC62109-1,2) | |
| EMC certification leve | En61000,C2 | |
| Operating temperature range | -15°Cto 55°C | |
| Storage temperature range | -25°C~60°C | |
| Humidity range | 5%to 95%(Conformal coating protection) | |
| Noise | ≤60dB | |
| Heat dissipation | Forced air cooling,variable speed of fan | |
| Communicati on interface | USB/RS485(/WiFi/GPRS)/Dry node control | |
| Size (L*W*D) | 415mm*280mm*100mm | |
| Weight(kg) | 7.8 | |