Product Category

Three-phase low-voltage 14–20 kW grid-connected inverters

1.100% unbalanced output, max. output up to 50% rated power for each phase
2.AC couple to retrofit existing solar system
3.Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
4.Max. charging/discharging current of 350A
5.48V low voltage battery, transformer isolation design
6.6 time periods for battery charging/discharging
7.Support storing energy from diesel generator
CONTACT US

Product Details

Product Specifications

Technical Data
Model SW-14K-SG05LP3 -EU-SM2  SW-15K-SG05LP3 -EU-SM2  SW-16K-SG05LP3 -EU-SM2  SW-18K-SG05LP3 -EU-SM2  SW-20K-SG05LP3 -EU-SM2 
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max.Charging Current(A) 260  280  300  330  350 
Max.Discharging Current(A) 260  280  300  330  350 
Charging Strategy for Li-ion Battery Self-adaption to BMS
Numberof BatteryInput 1
PV String Input Data          
Max.PVAccess Power(W) 28000 30000  32000  36000  40000 
Max.PVInput Power(W) 22400 24000  25600  28800  32000 
Max.PVInput Voltage(V) 800 
Start-up Voltage(V) 160 
MPPT Voltage Range(V) 160-650
Rated PV Input Voltage(V) 550 
Max.Operating PVInput Current(A) 36+36
Max.Input Short-Circuit Current(A) 54+54
No.of MPP Trackers/No.of Strings MPPTracker 2/2+2
ACInput/Output Data
Rated ACInput/Output Active Power(W) 14000 15000  16000  18000  20000 
Max.AC Input/Output Apparent Power(VA) 15400 16500  17600  19800  22000 
Rated ACInput/Output Current(A) 21.3/20.3 22.8/21.8 24.3/23.2 27.3/26.1 30.4/29
Max.AC Input/Output Current(A) 23.4/22.4 25/24 26.7/25.6 30/28.7 33.4/31.9
Max.Continuous ACPassthrough(grid to load)(A) 70
Peak   Power(off-grid)(W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated  Input/Output Voltage/Range(V) 220/380V,230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max.Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency  >99%
 Equipment Protection
Integrated DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch,
Insulation Impedance Detection, Residual Current Detection
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232/CAN
Monitor Mode  GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range (°C) -40 to +60°℃, >45°℃ Derating
 Permissible Ambient Humidity 0-100%
Permissible Altitude 3000m
Noise(dB) <60
Ingress Protection(IP) Rating IP65
Inverter Topology Non-lsolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 456x750x268.5 (Excluding Connectors and Brackets)
Weight(kg) 51.9
Type of Cooling Intelligent Air Cooling
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation  IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety/EMC Standard IEC/EN61000-6-1/2/3/4,IEC/EN62109-1,IEC/EN62109-2