24v/48v 4.2-12kw-EU IP54 Hybrid On/Off Grid Inverter ( 230V Series )
230V Series IP54 Hybrid On/Off Grid Inverter, models SW-4.2K-24V-EU, SW-6.2K-48V-EU and SW-12K-48V-EU. Up to 6 units can be paralleled.
It supports segmented charge & discharge and anti-backflow grid-tie function. It can operate without batteries, solar power and utility grid can supply loads together. Four charging modes are available: Solar Only, Grid Priority, Solar Priority and Hybrid Charging. Grid bypass enables uninterrupted power supply.
It supports segmented charge & discharge and anti-backflow grid-tie function. It can operate without batteries, solar power and utility grid can supply loads together. Four charging modes are available: Solar Only, Grid Priority, Solar Priority and Hybrid Charging. Grid bypass enables uninterrupted power supply.
| Product Specifications | |||
| Model | SW-4.2K-24V-EU | SW-6.2K-48V-EU | SW-12K-48V-EU |
| Parallel Operation Mode | |||
| Number of units in parallel | NO | 1~6 | 1~6 |
| Communication Mode | |||
| Rated Input Voltage | 230Vac±5% | ||
| Input Voltage Range | 170–280 VAC (UPS mode); 90–280 VAC (APL mode) | ||
| Frequency | 50 Hz/60 Hz (auto-detect) | ||
| Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz); 57±0.3Hz~65±0.3Hz(60Hz); |
||
| Overload/Short-Circuit Protection | Circuit Breakers and Fuses | ||
| Efficiency | >93% | ||
| Switchover Time (Bypass and Inverter) | ≤5ms | ||
| AC Reverse Protection | Yes | ||
| Maximum Bypass Phase Overload Current | 30A | 40A | 60A |
| Inverter Mode | |||
| Output Voltage Waveform | Pure Sine Wave | ||
| Rated Output Power (W) | 4200VA/4200W 6200VA/6200W 12000VA/12000W | ||
| Power Factor | 1 | ||
| Rated Output Voltage (Vac) | 230Vac | ||
| Output Voltage Error | ±5% | ||
| Output Frequency Range (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | ||
| Maximum Efficiency | >94% | ||
| Overload Protection | (102% < load < 125%) ± 10%: Report an error and shut off the output after 5 minutes; (125% < load < 150%) ± 10%: Report an error and shut off the output after 10 seconds; Load > 150% ± 10%: Report an error and shut off the output after 5 seconds; |
||
| Peak Power | 8400VA | 12000VA | 24000VA |
| Load Motor Performance | 2HP | 4HP | 8HP |
| Bypass Circuit Breaker Specifications | 32A | 40A | 63A |
| Rated Battery Input Voltage | 24V | 51.2 V (minimum startup voltage: 44 V) | |
| Battery Voltage Range | 20.0~30Vdc±0.6Vdc | 40.0 Vdc to 60 Vdc ±0.6 Vdc (undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery… can be set on the LCD screen) |
|
| Self-Discharge in Power-Saving Mode | Load≤25W | Load≤50W | |
| AC Charging | |||
| Battery Type | Lead-acid or lithium-ion batteries | ||
| Maximum Charging Current (Configurable) | 80A | 80A | 150A |
| Charging Current Tolerance | ±5Adc | ||
| Charging Voltage Range | 28~30Vdc | 40-60Vdc | |
| Short-Circuit Protection | Circuit Breakers and Fuses | ||
| Circuit Breaker Specifications | 40A | 40A | 63A |
| Solar Charging | |||
| Number of MPPT Channels | 1 | 1 | 2 |
| Maximum PV Open-Circuit Voltage | 500Vdc | ||
| PV Operating Voltage Range | 120~450VDC | 120Vdc~500Vdc | 120Vdc~500Vdc |
| MPPT Voltage Range | 90Vdc~450Vdc | 90Vdc~450Vdc | 90Vdc~450Vdc |
| Battery Voltage Range | 40-60Vdc | ||
| Maximum PV Input Power | 6000W | 6500W | 9000WX2 |
| Maximum PV Input Current | 20A | 27A | 27A+27A |
| Charging Short-Circuit Protection | Fuse Blown | ||
| Wiring Protection | Reverse Polarity Protection | ||
| Maximum Charging Current Specifications for Hybrid Charging (AC Charging + Solar Charging) | |||
| Maximum Charger Current (Configurable) | 0-100A | 0-100A | 0-150A |
| General Data | |||
| Operating Temperature Range | -20°C to 60°C (derated at 45°C) | ||
| Storage Temperature Range | -25°C to 60°C | ||
| Humidity Range | 5% to 95% (with protective coating) | ||
| Protection Rating | ≤60 dB | ||
| Noise Level | IP54 | ||
| Heat Dissipation | Forced air cooling with intelligent variable-speed fan | ||
| Communication Interfaces | USB/RS485 (Wi-Fi/4G)/dry contact control | ||
| Wi-Fi Capability | NO | Yes | |
| Product Dimensions/Packaging Dimensions (L x W x D) | 450x362x125mm/510×440×205mm | 486.5x325x125mm/550×375×200mm | 610×458x150mm/665×530×220mm |
| Net Weight/Packaging Weight (kg) | 9/10.5 | 10/11 | 19.5/21 |
| Optional Features | |||
| Parallel Operation Function | NO | ||
| Grid Reverse Current Protection CT | NO | ||