tPower-NL8 (100/110/125/136KT) Three-Phase Grid-Tied Inverter
tPower-NL8 100–136kW three-phase grid inverter for large industrial distributed PV plants. Up to 98.5% efficiency, 6–7 MPPT trackers, IP66 protection, built-in SVG function and cloud monitoring to boost power yield and grid stability.
| Product Model | tPower-NL8.100KT | tPower-NL8.110KT | tPower-NL8.125KT | tPower-NL8.136KT |
| DC-Side Parameters | ||||
| Start-up Voltage | 200V | |||
| Maximum DC Input Voltage | 1100V | |||
| Maximum Current per MPPT Channel | 48A | |||
| MPPT Voltage Range | 180~1000V | |||
| Rated Operating Voltage | 600V | |||
| Number of MPPT Channels | 6 | 7 | ||
| Number of Strings per MPPT Channel | 3 | |||
| AC-Side Parameters | ||||
| Rated Output Power | 100kW | 110kW | 125kW | 136kW |
| Maximum Output Power | 110kVA | 121kVA | 137.5kVA | 149.6kVA |
| Maximum Output Current | 167.1A | 183.8A | 208.9A | 227.2A |
| Rated Grid Voltage | 220V/380Vac | |||
| Grid Voltage Range | 323~418V | |||
| Rated Grid Frequency | 50Hz/60Hz | |||
| Grid Frequency Range | 45~55Hz/55~65Hz | |||
| Maximum Total Harmonic Distortion (at Rated Power) | <2% | |||
| Power Factor | >0.99 (rated power) / (0.8 leading to 0.8 lagging, adjustable) | |||
| DC Component | <0.5% (rated power) | |||
| Protection Functions | ||||
| Grid Monitoring | vailable | |||
| Anti-Islanding Protection | Available | |||
| Input Reverse Connection Protection | Available | |||
| Output Short-Circuit Protection | Available | |||
| Output Overvoltage Protection | Available | |||
| Output Overcurrent Protection | Available | |||
| Leakage Current Protection | Available | |||
| Surge Protection | DC Type I / AC Type II | |||
| Module-Level Insulation Resistance Testing | Available | |||
| AC/DC Terminal Temperature Monitoring | Available | |||
| Intelligent String Disconnection | Available | |||
| DC Switch | Available | |||
| String Monitoring | Available | |||
| Intelligent Arc Protection | Optional | |||
| Module PID Recovery | Optional | |||
| System Parameters | ||||
| Maximum Efficiency | 98.5% | |||
| China Efficiency | 98.1% | |||
| Humidity Range | 0–100%, no condensation | |||
| Cooling Method | Intelligent Air Cooling | |||
| Operating Temperature | -40~+60℃ | |||
| Nighttime Losses | <5W | |||
| Permissible Altitude | 5,000 m (>4,000 m derated) | |||
| Display | LED/APP/Web | |||
| Communication | RS485/Bluetooth/4G (optional communication dongle) + APP/PLC (optional) | |||
| Dimensions (W × H × D) | 1025*795*380mm | |||
| Weight | 100kg | |||
| Protection Rating | IP66 | |||
| Certification Standards | ||||
| Safety Standards / Electromagnetic Compatibility | NB/T 32004-2018,GB/T 37408-2019,IEC 62109-1/2 | |||