Product Category

SW1-12KW Horizontal Single-Phase Inverter

◆ Ring-core low-loss transformer with pure sine wave output;
◇ Real-time monitoring of various voltage parameters during operation;
◆ Multiple operating modes and battery types adjustable by the user, offering broader application possibilities;
◇ Various battery parameters adjustable by the user to meet diverse operational requirements;
◆ Features frequency adaptation to accommodate power grids with different frequencies;
◆ Wall-mounted design for easy installation;
CONTACT US

Product Details

Product Specifications

Basic Information
Model SW-     10212/24 20224/48 30224/48 40248  50248  60248  80248  100248  120248 
Rated Power     1000w 2000w 3000w 4000w 5000w 6000w 8000w 10000w 12000w
Peak Power (20 ms)     2000w 4000w 6000w 8000w 10000w 12000w 14000w 16000w 18000w
Nominal Battery Input Voltage     12/24vdc 24/48vdc 48vdc 48/96vdc
Unit Dimensions (L x W x H, mm)     495*270*195 560*290*195 655*332*260
Packaging Dimensions (L x W x H, mm)     530*295*250
Net Weight (kg)     11.5  15  17.5  21.5  24.5  27  50  52  54 
Gross Weight (kg)     15.5  19  21.5  26.5  29.5  32  55  58  61 
Mounting Method Wall-mounted (horizontal)
General Information
Input DC Input Voltage Range 12V system: 10.515 VDC; 24V system: 2130 VDC; 48V system: 4260 VDC
Mains Input Voltage Range 110VAC±20%/220VAC±20% 85-138VAC;170-275VAC
Mains Input Frequency Range 45-65Hz
Mains Charging Current 030 A (customizable) 30A (default)  C0C6 can be configured
Output Inverter Output Waveform Pure sine wave
Inverter Output Voltage 110VAC±2%/220VAC±2% 110 VAC/127 VAC; 220 VAC; ±5% (inverter mode)
Inverter Output Frequency 50Hz±0.5Hz or 60Hz±0.5Hz 50/60 Hz ±1% (auto-detection)
Inverter Output Efficiency 85%
Inverter Output Waveform Distortion ≤3% (linear load) 
Mains Output Voltage Range Follows mains input  
Mains Output Frequency Range Automatic tracking 
No-Load Loss ≤1% of rated power in inverter mode; ≤5 W in energy-saving mode
Battery Type Available Models Lead-acid, gel, lithium iron phosphate, ternary lithium, custom The UO-U7 can be configured
Protection Battery Protection Low/High Battery Voltage Protection
Temperature Protection Internal Over-Temperature Protection
Output Protection Output Overload/Short-Circuit Protection
Operating Mode     Battery Priority/Mains Priority/Energy-Saving Priority Modes
Mains Power Switching Time     4ms
Panel Display     LCD+LED
Cooling Method     Intelligent fan cooling 
Communication Features RS232 (optional)
Environment Operating Ambient Temperature -10~40
Storage Ambient Temperature -15~60
Operating Noise Level 55dB
Operating Altitude 2000 m (derating required above this altitude)  
Operating Relative Humidity 0%–95%, non-condensing  
Warranty One year